Caution – TOA Electronics SSDVT-4035CNM User Manual

Page 32

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

32

Figure 56

Burner Flame Appearance Models -

SSDV-3530 & SSDV-4045 Series

Burner Air Shutter Adjustment

Main Burner Factory Air Shutter

Opening Setting - Inches (millimeter)

Model

Natural

Gas

Propane

Gas

SSDVT-3530

1/4

(6.35 mm)

1/2

(12.7 mm)

SSDVR-3530

1/4

(6.35 mm)

1/2

(12.7 mm)

SSDVT-4035

1/4

(6.35 mm)

1/2

(12.7 mm)

SSDVR-4035

1/4

(6.35 mm)

1/2

(12.7 mm)

Adjustment
Rod Up
(Fully Open
Position)

Air Shutter

Adjustment Rod
Down (minimum
air opening
position)

Burner
Tube

Adjustment Setscrew

Figure 57

Combustible Finished

Wall Materials

Top of Appliance

Combustible material may
touch the appliance top

Louvers

Top of Door Frame

Hood must be installed as shown.

3"

(76 mm)

This Area Must
Remain Clear of
Combustible
Materials

1 in. Min.

(25 mm)

Drywall Bracket / Spacer

Top Spacers

Figure 58

- Combustible Wall Framing

Step 11. HOOD INSTALLATION

(Refer to Figure 58)
All of these appliances must have hoods installed prior to operat-
ing.

Slide the hood into the slots on the lower edge of the cabinet top.

FINISHING REQUIREMENTS - Wall Details

Complete fi nished interior wall. To install the appliance facing fl ush
with the fi nished wall, position framework to accommodate the thick-
ness of the fi nished wall (Figure 5 8 )
.

See Page 6 for Cold Climate Insulation

and Page 9 for Clearances

Burner Air Shutter Adjustment Procedure

CAUTION

The air shutter door and nearby appliance surfaces are
hot. Exercise caution to avoid injury while adjusting
fl ame appearance.

Burner Air Shutter Adjustment Procedure

1. Locate adjustment rod and adjust air shutter to the standard setting

as shown in Figure 57 (adjustment rod is located in the lower control
compartment).

Note: Move the adjustment rod down to decreases air and up to

increases.

2. Light appliance (follow lighting procedure on lighting label in control

compartment or see homeowners manual).

3. Allow the burner to operate for at least 15 minutes while observing

the fl ame continuously to ensure that the proper fl ame appearance
has been achieved (see Figure 56). If the following conditions are
present, adjust accordingly.

• If

fl ame appears weak or sooty, adjust air shutter, incrementally, to a

more open position until the proper fl ame appearance is achieved.

• If

fl ame stays lowered blue, adjust air shutter, incrementally, to a more

closed position until the proper fl ame appearance is achieved.

4. Leave the control knob (off/pilot/on) in the ON position and the burner

OFF/ON switch OFF (& remote switches, if applicable).

5. When satisfi ed that the burner fl ame appearance is normal, re-install the

lower control compartment door then proceed to fi nish the installation.