TOA Electronics SSDVT-4035CNM User Manual

Page 23

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

23

V

H2

H1

H

Wall Firestop/Spacer

(SV4.5HF)

Ceiling

Firestop/Spacer

(SV4.5VF)

When using Secure Flex,

use Firestop/Spacer

SF4.5VF.

When using Secure

Flex, use Firestop/Spacer

SF4.5HF.

V

H

H1

V1

Wall Firestop/Spacer

(SV4.5HF)

Ceiling

Firestop/Spacer

(SV4.5VF)

When using Secure Flex,
use Firestop/Spacer

SF4.5VF.

When using Secure

Flex, use Firestop/Spacer

SF4.5HF.

Wall Firestop/Spacer

(SV4.5HF)

Table K

H

+ H

1

+ H

2

Maximum

H

Maximum

V Minimum

feet

(meter)

feet

(meter)

feet

(meter)

5

(1.524)

2

(0.610)

1

(0.305)

10

(3.048)

4

(1.219)

2

(0.610)

15

(4.572)

6

(1.829)

3

(0.914)

20

(6.096)

8

(2.438)

4

(1.219)

V + H + H1 + H2 = 40 feet (12.2 m) Max

H = 8 feet (2.438 meters) Max.

H + H1+ H2 = 20 feet (6.096 meters) Max.

Example: If 20 feet total (H+H

1

+H

2

) horizontal vent

run is needed, then 4 feet minimum of (V) vertical
vent will be required.

This table shows a 1(V) to 5(H) ratio. For every
1 foot of (V) vertical, you are allowed 5 feet of
horizontal run up to a maximum total (H+H

1

+H

2

)

horizontal run of 20 feet.

Figure 40

- Top Vent - THREE 90 DEGREE ELBOWS

Figure 39

- Rear Vent - THREE 90 DEGREE ELBOWS

See Table 12 on Page
21 as an aid in venting
component selection for
a particular range of exte-
rior wall thicknesses.

See Table 12 on Page 21 as an aid in venting
component selection for a particular range of
exterior wall thicknesses.

HORIZONTAL VENT FIGURES / TABLES (CONTINUED)

Square termination
(SV4.5HT-2) shown.

Square termination (SV4.5HT-2) shown.

Table L

H

+ H

1

Maximum

V Minimum

feet

(meter)

feet

(meter)

5

(1.524)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

H

+ H

1

= 20 feet (6.096 m) Max.

V

+ V

1

+

H

+ H

1

= 40 ft. (12.192 m) Max.

Example: If 20 feet total (H+H

1

) horizontal vent

run is needed, then 4 feet minimum of (V) vertical
vent will be required.

This table shows a 1(V) to 5(H) ratio. For every 1
foot of (V) vertical, you are allowed 5 feet of (H+
H

1

) horizontal run, up to a maximum horizontal

run of 20 feet.

An elbow is acceptable as 1 foot of vertical rise
except where an elbow is the only vertical com-
ponent in the system. See Figure 35.