36

Note - Use extra care not to engage the
orifi ce strip with the 7/16" open end wrench
(contacting the orifi ce strip could cause strip
distortion rendering the pilot inoperative).
Also avoid wrench contact to any of the
other pilot parts.

Use a 7/16" open end wrench and turn the
pilot hex fi tting counter-clockwise 1/4 turn.
(See Figure 63).

Note - The orifi ce strip tab may be randomly
located on any side of the hex fi tting.
d. Push the orifi ce strip tab all the way
against the hex fi tting to align the appropri-
ate gas type orifi ce (see Figures 62 & 63)
.
The type of gas for which the pilot is set,
is, the gas type shown on the tab.

e. Retighten, clockwise, the pilot hex
fi tting until the pilot hood aligns with the
thermocouple and thermopile as indicated
by the arrows shown in Figure 63
.

Adjusting Knob

Conversion screw
(blue natural gas;
red LP/propane gas)

Regulator Cap

Honeywell Millivolt Gas Valve

Figure 61

Pilot for Honeywell Millivolt Gas Valve

Figure 62

b. Attach manometer to the manifold side
pressure test fi tting and verify manifold
pressure reads 3.5 inches water column
(0.87 kPa) for natural gas, and 10.0
inches water column (2.49 kPa) for pro-
pane gas.

c. Convert the pilot orifi ce as follows (see
Figures 62 & 63
):

b. Attach manometer to the manifold side
pressure test fi tting and verify manifold
pressure reads 3.5 inches water column (0.87
kPa) for natural gas, and 10.0 inches water
column (2.49 kPa) for propane gas.
c. Refer to Figure 60 and remove the pilot
hood assembly to access the hexed pilot orifi ce.
Remove and replace the orifi ce with the one
provided with the kit.

Step 5. Millivolt Appliances

Honeywell Systems -

a. Convert the gas valve as follows
(see Figure 61): Remove the plastic protecting
cap. Remove the gas type setting screw by
turning it counterclockwise. Obtain the replace-
ment gas type setting screw from the kit and
screw it into place (red for propane and blue
for natural gas). Tighten the gas type setting
screw by turning it clockwise. Replace the
plastic protecting cap.

Pilot for Honeywell Millivolt Gas Valve

(Loosening of Hex Fitting For

Orifi ce Strip Tab Positioning)

Figure 63

7/16 in. Open
End Wrench

Hood

Hood
Alignment

Orifi ce
Strip Tab

Take care not to contact the orifi ce strip tab
with the hex fi tting wrench - distortion of the
tab may render the pilot inoperative.

LP (propane) Gas Posi-
tion - 1/16 inch hole,
LP and red color shown
on tab.

Natural Gas Position
- NAT shown on tab.

Top View of Hex Fiting and Orifi ce Strip Tab

Orifi ce Strip Tab Position Identifi cation

For LP (propane gas) and Natural Gas

P

L

NAT

SIT Millivolt Gas Valve

Pilot for SIT Millivolt

Gas Valve

Figure 60

Pressure

Regulator

Remove
These
Components

Figure 59

Pilot
Orifi ce

Gas conversion kits are available to adapt the
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete the
task including labeling that must be affi xed to
ensure safe operation.

Kit part numbers are listed here and the following
steps detail the conversion procedure.

Step 1. Turn off the gas supply to the appliance.
Remove the front glass door/frame from the
appliance. Access the control compartment.

Step 2. Carefully remove the logs. Exercise care
so as not to break the logs.

Step 3. Locate the screws securing the burner
assembly to the appliance. Remove the burner
assembly and retain the securing screws.

Step 4. Millivolt Appliances - SIT Systems

a. See Figure 59 and the instructions
provided with the kit. Using a Torx T20,
tool or or standard fl at screwdriverremove
and discard the three pressure regulator
mounting screws. Remove the pressure
regulator, spring, poppet, diaphragm and
bushing. Discard all removed components.
Ensure the rubber gasket installed on the
back of the replacement pressure regulator
is properly positioned and install the new
pressure regulator using the new screws
supplied with the kit. Tighten screws to 25
In. lb. torque.

IMPORTANT

LE CANADA SEULEMENT

La conversion devra être effectuée
conformément aux recommanda-
tions des autorités provinciales
ayant juridiction et conformément
aux exigences du code d'installation
CAN1-B149.1 ET.2.