New york city, new york (mea), Table 2, Table 3 – TOA Electronics SSDVT-4035CNM User Manual

Page 3: Table 4, Table 5, Table 7, Table 6, Table 1, Sit millivolt gas valve, Figure 1 figure 3 honeywell electronic gas valve

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

New York City, New York (MEA)

Installation of these fi replaces are approved
for installation in New York City in the US state
of New York.

These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than
1/2 psig (3.5 kPa).

These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve
) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).

Orifi ce Sizes - Sea Level to High Altitude
(All Models)

These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard
burner orifice sizes (marked with an "*" in
Table 7). For elevations above 4500 feet,
contact your gas supplier or qualifi ed service
technician . Install the appliance according to
the regulations of the local authorities having
jurisdiction and, in the USA, the National Fuel
Gas Code NFPA 54 / ANSI Z223.1 - latest edition
or, in Canada, the CAN1-B149.1 and .2 codes
- latest edition.

Input (BTU) Manually-Modulated Gas

Valves (millivolt models)

* PROPANE GAS

Models

Input Rate (BTU / HR)

SSDV-3530CPM

23,000 high

17,500 low

SSDV-4035CPM

29,000 high

22,500 low

Table 2

Electronic Models
Electronic models have a fi xed rate gas valve.
Input of electronic models is shown in

Table 3.

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate (BTU / HR)

SSDV-3530

23,000

SSDV-4035

29,000

Table 3

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 4

Gas Pressure - All Models
Tables 4, 5 and 6
show the appliances' gas
pressure requirements:

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane

(Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 5

Test gauge connections are provided on the
front of the millivolt gas control valve, identi-
fi ed IN for the inlet and OUT for the manifold
side. A 1/8" NPT Test gauge connection
is provided at the inlet and outlet side of

the electronic gas control valve.

Burner Orifi ce Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model
Series

Natural

Gas

drill size

(inches)

Propane

Gas

drill size (inches)

SSDV-3530

2.3 mm (.090")

*

37L70 •

#54 (.055")

*

99K79 •

SSDV-4035

#36 (.1065")

*

18L4001 •

#52 (.0635")

*

LB-55874D •

* Standard size installed at factory
• Part /Cat. Number

Table 7

Manifold Gas Supply Pressure

(electronic models)

Fuel #

Max. Manifold Pressure

Natural Gas

(Hi) 3.5" WC (.87 kPa)

Propane

(Hi) 10.0" WC (2.49 kPa)

Table 6

* If fi eld converted - see Pages 35-37

Input (BTU) Manually-Modulated Gas

Valves (millivolt models)

NATURAL GAS

Models

Input Rate (BTU / HR)

SSDV-3530CNM

23,000 high

17,500 low

SSDV-4035CNM

29,000 high

21,500 low

Table 1

HI

LO W

HT

PT

HT

PT

PILO

T

PIL

O

T

ON

it

OFF

IN

OUT

Manifold Pressure Tap

Inlet Pressure Tap

SIT Millivolt Gas Valve

Pilot Adjustment
Screw

HI/LO Variable
Flame Height
Adjustment

Main Gas

Control Knob

OFF/PILOT/ON

Figure 1

Figure 3

Honeywell Electronic Gas Valve

F

F

O

NI

P

S

I

N

O

L

O

R

T

N

O

C

GI

N
TI

ER

Manifold Pressure
Port

ON / OFF Switch

Inlet
Pressure
Port

Electronic Gas
Control Valve

O

N

OF

F

PI

LOT

L

O

H

I

Figure 2

GAS CONTROL
KNOB

CONVERTIBLE
HI/LO REGULATOR
(adjusts fl ame height
and heat output)

INLET
PRESSURE
TAP

PILOT
ADJUSTMENT
SCREW

WIRING
TERM-
INALS

OUTLET
PRESSURE
TAP

TP/TH

PIEZO
IGNITER

TH

TP

Honeywell Millivolt Gas Valve

Advertising