Texas Instruments TMS320F2802 User Manual

Page 113

Advertising
background image

t

w(WAKE-INT)

t

d(WAKE-STBY)

t

d(IDLE−XCOL)

Wake−up

Signal

X1/X2 or

X1 or

XCLKIN

XCLKOUT

STANDBY

Normal Execution

STANDBY

Flushing Pipeline

(A)

(B)

(C)

(D)

(E)

(F)

Device

Status

TMS320F2809, TMS320F2808, TMS320F2806

TMS320F2802, TMS320F2801, TMS320C2802

TMS320C2801, TMS320F28016, TMS320F28015

www.ti.com

SPRS230N – OCTOBER 2003 – REVISED MAY 2012

Table 6-18. STANDBY Mode Timing Requirements

TEST CONDITIONS

MIN

NOM

MAX

UNIT

Without input qualification

3t

c(OSCCLK)

Pulse duration, external

t

w(WAKE-INT)

cycles

wake-up signal

With input qualification

(1)

(2 + QUALSTDBY) * t

c(OSCCLK)

(1)

QUALSTDBY is a 6-bit field in the LPMCR0 register.

Table 6-19. STANDBY Mode Switching Characteristics

PARAMETER

TEST CONDITIONS

MIN

TYP

MAX

UNIT

Delay time, IDLE instruction

t

d(IDLE-XCOL)

32t

c(SCO)

45t

c(SCO)

cycles

executed to XCLKOUT low

Delay time, external wake signal
to program execution resume

(1)

Without input qualifier

100t

c(SCO)

Wake up from flash

cycles

Flash module in active

With input qualifier

100t

c(SCO)

+ t

w(WAKE-INT)

state

t

d(WAKE-STBY)

Without input qualifier

1125t

c(SCO)

Wake up from flash

cycles

Flash module in sleep

With input qualifier

1125t

c(SCO)

+ t

w(WAKE-INT)

state

Without input qualifier

100t

c(SCO)

cycles

Wake up from SARAM

With input qualifier

100t

c(SCO)

+ t

w(WAKE-INT)

(1)

This is the time taken to begin execution of the instruction that immediately follows the IDLE instruction. execution of an ISR (triggered
by the wake up signal) involves additional latency.

A.

IDLE instruction is executed to put the device into STANDBY mode.

B.

The PLL block responds to the STANDBY signal. SYSCLKOUT is held for approximately 32 cycles (if CLKINDIV = 0)
or 64 cycles (if CLKINDIV = 1) before being turned off. This delay enables the CPU pipe and any other pending
operations to flush properly.

C.

Clock to the peripherals are turned off. However, the PLL and watchdog are not shut down. The device is now in
STANDBY mode.

D.

The external wake-up signal is driven active.

E.

After a latency period, the STANDBY mode is exited.

F.

Normal execution resumes. The device will respond to the interrupt (if enabled).

Figure 6-15. STANDBY Entry and Exit Timing Diagram

Copyright © 2003–2012, Texas Instruments Incorporated

Electrical Specifications

113

Submit Documentation Feedback

Product Folder Link(s):

TMS320F2809 TMS320F2808 TMS320F2806 TMS320F2802 TMS320F2801 TMS320C2802

TMS320C2801 TMS320F28016 TMS320F28015