Features and benefits (10–15ton), Features and benefits, 10–15 ton) – Trane CG-PRC007-EN User Manual

Page 5: Flexibility

Advertising
background image

5

CG-PRC007-EN

Features and
Benefits

The 10 and 15-ton air-cooled Cold
Generator

chillers, with Trane direct

drive hermetic scroll compressors, has
outstanding standard features and
additional benefits that make selection,
installation, and servicing easy.

Flexibility

Footprint

Central to the design of any project is the
operating envelope of the air-cooled
packaged chiller. With this in mind, Trane
builds the chillers to make the most
efficient use of the available installation
space. The Trane CGA model chillers are
extremely compact. They have the
lightest weight, the smallest footprint,
and the lowest silhouette of any chiller in
the industry.

Less Weight

These lightweight models afford less
stress on building supports and greater
handling ease.

Installation

Installation time and effort are reduced
when dealing with a significantly smaller
and lighter unit. In addition, having
electrical and water connections on the
same side of the unit and a single-point
main power connection serves to make
installation easier. The unit arrives at the
jobsite fully assembled, tested, charged
and ready to provide chilled water.

Ease of Service

The control panel and unit panels are
completely removable for service
accessibility and convenience.

ICS Interface

Communication with Trane Tracer

or

Tracker

is possible through the ICS

Interface on the 10 and 15 ton Cold
Generator chiller.

Optional Features

Hot Gas Bypass — Allows unit

operation below the minimum step of
unloading.

Low Ambient Head Pressure Control

— Modulates the rpm of the fan motor
in response to outdoor ambient
temperature and unit head pressure.
Provides unit cooling operation down
to outdoor temperatures of 0°F.

Coil Guard — Metal grille with PVC

coating to protect the condenser coil.

Isolation — Neoprene in shear or

spring flex isolators.

Power Supply Monitor — Provides

protection against phase loss, phase
reversal, phase imbalance, incorrect
phase sequence and low line voltage.

Elapsed Time Meter/Number Starts

Counter — Records number of
compressor starts and operating
hours.

Flow Switch — Required as a safety

interlock to prevent operation of unit
without evaporator flow (available
option for field installation only).

Integrated Comfort Systems (ICS)

Interface — Provides the ability to
communicate with Trane Tracer or
Tracker building management systems
via a Thermostat Control Module —
(TCM).

Gauges — Monitor suction and

discharge pressures.

(10–15 Ton)