B–78

Operator Manual

Physical Configurations

Weight

115.4 lbs.

Dimensions

Width:

28.3 inches

Height:

13.0 inches

Depth:

14.4 inches

Depth with paper exit guide assembly:

23.4 inches

Preventive Maintenance

This printer is designed to eliminate the requirement of scheduled mainte-
nance procedures, such as alignment, adjustment, or lubrication. Preventive
maintenance is limited to periodic cleaning. Dust and paper fibers should be
removed periodically with a soft cloth and brush or a vacuum cleaner. Clean
the printer case with a damp cloth and soapy water. DO NOT use any abrasive
cleaners or solvents, as they will damage the case.

Environment

Operating

Temperature (Dry Bulb):

50°F to 104°F (10°C to 40°C)

Humidity:

10 to 90% noncondensing with a maximum wet bulb
temperature of 82°F (28°C) and a minimum dew point of
36°F (2°C )

Altitude:

To 8,000 ft. (2438 meters)

Nonoperating

Temperature:

Boxed:

-40°F to 151°F (-40°C to 66°C)

Unboxed:

14°F to 122°F (-10°C to 50°C)

Humidity:

10 to 95% noncondensing

Altitude:

To 10,000 ft. (3048 meters)

Thermal Shock:

61°F (20°C) per hour

Vibration:

Units meet NSTA (National Safe Transit Association)
requirements.

Safety

Personnel hazard areas have restricted access with appropriate warning labels.
Catastrophic equipment failures are inhibited with protective functions in
major areas of overload potential.

Industry and Agency Standards