Appendix B: Specifications

B–79

Cooling System

Cooling system malfunctions are detected and a failure will result in shuttle
motion, paper motion, and printing functions being inhibited. The malfunc-
tion Hammer Voltage1 will be reported on the control panel display.

Acoustics

The Sound Power Level is a 9 position average, per ISO 7779. The Sound
Pressure Level is a 4 position average, per ISO 9296.

Sound Pressure Level

Sound Power Level

55 dB(A)

7.0 Bel

Environment

Power Supply

The printer requires single phase, 47 to 63 Hz. 90 to 264 VAC input power. The
printer’s universal power supply automatically adjusts to the correct values. A
fuse is provided to interrupt power to the power supply. The following table
gives typical current values.

2900 Current/Wattage Requirements @ Nominal Voltage

AC Volts

Freq.

Average Peak

Average Average

(RMS) (Hz)

Operating

Operating

Idle (<5 min.)

Idle (>5 min.)

110

50

1.0 A/055 W

2.3 A/250 W

0.3 A/35 W

0.2 A/19 W

110

60

1.0 A/105W

2.3 A/250W

0.3 A/35W

0.2 A/19 W

220

50

0.5 A/105W

1.2 A/250W

0.2 A/35W

0.1 A/19W

Heat Load Contribution

The average heat load contribution to the environment is approximately 735
BTUs per hour (215 Watts). The minimum heat load contribution is approxi-
mately 100 BTUs per hour (30 watts). The maximum is 2050 BTUs per hour
(600 Watts), under continuous full-load printing conditions.

Printing Conditions (110 VAC/60 Hz)

Wattage

BTU/Hr

Power On, not printing

55 W

188

100% Uppercase Rolling ASCII

400W

1370

Black Page Plot

600 W

2050