rtsp://<servername>/<network_rtsp_s<0~m-1>_accessname>

“m” is the stream number�

For detailed streaming protocol, please refer to “control signaling” and “data format” documents�

Camera Control

Note: This request requires privilege of viewer

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/viewer/camctrl.cgi?[channel=<value>][&camid=<value>][&move=<value>][&focus=

<value>][&iris=<value>][&speedpan=<value>][&speedtilt=<value>][&speedzoom=<value>] [&speedapp=<value

>][&auto=<value>][&zoom=<value>][&speedlink=<value>][&return=<return page>]

Parameter

Value

Description

channel

<0~(n-1)>

Channel of video source

camid

0,<positive integer>

Camera ID

move

home

Move to camera to home position

up

Move the Network Camera up

down

Move the Network Camera down

left

Move the Network Camera left

right

Move the Network Camera down

speedpan

-5 ~ 5

Set the pan speed

speedtilt

-5 ~ 5

Set the tilt speed

speedzoom

-5 ~ 5

Set the zoom speed

speedapp

-5 ~ 5

Set the auto pan/patrol speed

auto

pan

Auto pan

patrol

Auto patrol

stop

Stop camera

zoom

wide

To zoom for larger view with current speed

tele

To zoom for farer view with current speed

focus

far

To focus on farer distance

near

To focus on nearer distance

iris

auto

Let the Network Camera control iris size

open

Manually control the iris for bigger size

close

Manually control the iris for smaller size

speedlink

0 ~ 4

Issue speed link command�

return

<return page>

Redirect to the page <return page> after the parameter

is assigned. The <return page> can be a full URL path
or relative path according to the current path� If you omit
this parameter, it will redirect to an empty page�

Recall

Note: This request requires privilege of viewer

Method: GET

Syntax:

http://<servername>/cgi-bin/viewer/recall.cgi?recall=<value>[&channel=<value>][&return=<return page>]

Parameter

Value

Description

recall

Text string less than 30
characters

One of the present positions to recall�