Wolf Appliance Company SO30F/S User Manual

Page 100

Advertising
background image

Dimensions in
parentheses are in
millimeters unless
otherwise specified.

W O L F C O O K T O P V E N T I L A T I O N

100

B L O W E R C O N S I D E R A T I O N S

Except for Models DD30I, DD36I and DD45I,

which include a 500 CFM internal blower, Wolf

downdrafts are shipped without the blower

assembly. In-line and remote blower assemblies

are available. The blower will vary in size and is

dictated by the cooking surface, the volume of

air that needs to be moved and the length of the

duct run. A straight, short duct run with a

limited number of elbows and transitions will

allow the ventilation hood to perform most effi-

ciently.

Wolf downdraft ventilation systems are designed

for use with 3

1

/

4

" (83) x 10" (254) ductwork for

Models DD30I, DD36I and DD45I and 3

1

/

4

" (83) x

14" (356) ductwork for Models DD30R, DD36R

and DD45R. Each can be transitioned to 8" (203)

or 10" (254) round ductwork.

A remote-mounted blower will minimize the

amount of blower noise, but will not eliminate

the noise completely.

IMPORTANT NOTE: Install this downdraft

system only with a Wolf blower.

Refer to the cooktop ventilation recommenda-

tions on pages 115–116.

E L E C T R I C A L R E Q U I R E M E N T S

Wolf downdraft ventilation systems require a

separate, grounded 120 V AC, 60 Hz power

supply. The service should have its own 15 amp

circuit breaker, and a grounded 3-prong recepta-

cle should be located within reach of the 2

1

/

2

'

(.8 m) power cord. The specific location of the

outlet is not critical as long as it is within reach

of the power cord that is located midway, top

and bottom, on the right side of the downdraft.

IMPORTANT NOTE: If Model DD30 is to be

installed in a 30" (762) wide cabinet, Model

DD36 in a 36" (914) wide cabinet or Model DD45

in a 45

1

/

2

" (1156) wide cabinet, the electrical

outlet cannot be located on the back wall of the

cabinet. The outlet may be placed in adjacent

cabinetry.

Locate electrical within the shaded area shown

in the Installation Specifications illustrations.

IMPORTANT NOTE: A ground fault circuit

interrupter (GFCI) is not recommended and may

cause interruption of operation.

You must follow all National Electrical Code

regulations. In addition, be aware of local codes

and ordinances when installing your service.

36"

min (914)

FOR MODEL DD36

4 5

1

/

2

"

min (1156)

FOR MODEL DD45

30"

min (762)

FOR MODEL DD30

OPTIONAL

ELECTRICAL

LOCATION IN

ADJACENT RIGHT

SIDE CABINET

E

E

3

1

/

2

"

(89)

4"

min (102)

10"

(254)

24 "

min (610)

CABINET DEPTH

I N S T A L L A T I O N S P E C I F I C A T I O N S

Location of Electrical Supply

IMPORTANT NOTE:
Certain installations
may require that the
electrical supply be
placed in an adjacent
cabinet within reach of
the power cord.
Choose the location
shown in the illustra-
tion that best suits
your installation.