W O L F G A S R A N G E S

79

P L A N N I N G I N F O R M A T I O N

Wolf gas ranges come in 30" (762), 36" (914),

48" (1219) and 60" (1524) widths. Specifications

on the following pages provide overall dimen-

sions, finished rough opening dimensions and

installation specifics for each size of gas range.

We have minimized the information contained

in the illustrations, concentrating on the critical

information you need to plan your installation.

IMPORTANT NOTE: Caution must be used in

planning the proper installation of the Wolf gas

range to avoid fires or damage to adjacent

cabinetry or kitchen equipment. Please follow

the minimum clearances established in the

finished rough opening dimensions. Refer to

specifications on the following pages for your

model.

It is recommended that you use a Wolf Pro

ventilation hood or hood liner with the Wolf gas

range. Refer to pages 102–114 for Pro ventilation

specifications.

E L E C T R I C A L

|

G A S R E Q U I R E M E N T S

The Wolf gas range requires a 110/120 V AC,

50/60 Hz electrical supply to operate the elec-

tronic ignition system. The power supply cord is

equipped with a 3-prong, grounded plug for

protection against shock hazard. The service

should have its own 15 amp circuit breaker.

IMPORTANT NOTE: A ground fault circuit

interrupter (GFCI) is not recommended and may

cause interruption of operation.

Locate electrical and gas supply within the

shaded area shown in the Installation

Specifications illustration for your model.

Wolf gas ranges are designed to operate on

natural gas at 5" (12.5 mb) WC (water column)

pressure or LP (propane) gas at 10" (25 mb) WC

pressure. The minimum line pressure for natural

gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC

for LP gas. The maximum gas supply pressure to

the regulator should never exceed 14" (34.9 mb)

WC, .5 psi (3.5 kPa).

Wolf recommends the use of a

1

/

2

" (13) I.D.

commercial-type flex hose; this is the minimum

size that may be used. All plumbing to the flex

hose must be

3

/

4

" (19) minimum I.D. pipe.

IMPORTANT NOTE: A separate external gas

shut-off valve must be located near the range

in an accessible location.

You must follow all National Electrical Code and

gas regulations. In addition, be aware of local

codes and ordinances when installing your

services.

H I G H A L T I T U D E

The Wolf gas range
functions up to
6,000' (1828 m) in
altitude without any
adjustment. If the
installation is above
6,000' (1828 m),
contact your Wolf
dealer.

B U R N E R R A T I N G

Gas Ranges

Surface Burners

16,000 Btu/hr
(4.7 kW) with
500 Btu/hr (.1 kW)
delivered at simmer

Infrared Charbroiler 16,000 Btu/hr

(4.7 kW)

Infrared Griddle

18,000 Btu/hr
(5.3 kW)

Infrared Double

(2) 18,000 Btu/hr

Griddle

(5.3 kW)

French Top

15,000 Btu/hr
(4.4 kW)

Oven Burner (Bake)

30,000 Btu/hr
(8.8 kW)

Infrared Oven Broiler 18,000 Btu/hr

(5.3 kW)

Refer to the specific model requirements
for risers in non-island installations.