Wolf Appliance Company SO30F/S User Manual

Page 115

Advertising
background image

V E N T I L A T I O N R E C O M M E N D A T I O N S

115

C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S

INTERNAL BLOWERS

IN-LINE BLOWERS

REMOTE BLOWERS

CFM

450

500

600

900

600

1100

600

900

1200

1500

Cooktop Hoods

CTWH30

801643

808331

808332

801640

801641

801642

804701

CTWH36

801644

801645

808331

808332

801640

801641

801642

804701

IH4227

801644

801645

808331

808332

801640

801641

801642

804701

Downdraft Ventilation Systems

DD30I

Included

DD30R

808332

801641

801642

804701

DD36I

Included

DD36R

808332

801641

801642

804701

DD45I

Included

DD45R

808332

801641

801642

804701

M I N I M U M C F M R E C O M M E N D A T I O N S F O R W O L F C O O K I N G P R O D U C T S

COOKTOP HOODS

DOWNDRAFTS

PRO HOODS

MODEL

CFM

CFM

CFM

Cooktops and Integrated Modules

CT15I, CT15E, CT15G, IG15*, IS15*, IF15* and IM15

215

150

215

CT30I, CT30IU, CT30E, CT30EU and CT30G

450

350

500

CT36I, CT36IU, CT36E, CT36EU and CT36G

600

500

500

Dual Fuel Ranges

DF304

500

DF366, DF364C and DF364G

900

DF486C, DF486G, DF484CG, DF484DG and DF484F

1100

DF606DG, DF606F, DF606CG, DF604CF and DF604GF

1500

Sealed Burner Rangetops

SRT304

500

500

SRT366

500

900

SRT364C and SRT364G

900

SRT486C, SRT486G, SRT484CG, SRT484DG and SRT484F

900

Gas Ranges

R304

500

R366, R364C and R364G

900

R488, R486C, R486G, R484CG, R484DG and R484F

1100

R606DG, R606F and R606CG

1500

Gas Rangetops

RT366, RT364C, RT364G and RT362F

900

RT488, RT486C, RT486G, RT484CG, RT484DG and RT484F

1100

CFM recommendations are based on
total Btu/hr output. Wolf recommends
1 CFM per 100 Btu/hr (.03 kW).

*Downdraft systems are not recommended for use with the electric grill, steamer and fryer modules.