19

CONNECTING TO THE
ELECTRICITY SUPPLY

WARNING: THIS APPLIANCE MUST BE EARTHED.

DO NOT EARTH THIS APPLIANCE TO THE GAS
SUPPLY PIPING.
This appliance must be connected to 230V-240V
A.C. 50Hz supply. It is supplied with 2 metres of 5
amp 3 core cable incorporating a moulded 13 amp
plug, fitted with a 3 amp fuse, which can be plugged
directly into the nearest suitable socket. If this is not
long enough, the supply cable can be replaced
totally by a longer cable at least 0.75mm

2

nominal

cross sectional area (24/0.2mm). Ensure the plug is
accessible to the user.
IF THE MOULDED PLUG IS CUT FROM THE
CABLE FOR ANY REASON, IT MUST BE
DESTROYED OR DISPOSED OF SAFELY, AS
THE PROTRUDING WIRES WILL BE AN
ELECTRIC SHOCK HAZARD.

If any other type of plug is used it should incorporate
a 3 amp fuse in either the plug or adapter or at the
distribution board.
If the cable has to be threaded through small
apertures in cabinets etc., it may be disconnected
from the appliance, then re-connected to as shown
in Fig.2.
DO NOT EXTEND THE CABLE USING PLASTIC
OR CERAMIC CONNECTION TERMINAL BLOCKS
AND/OR INSULATION TAPE.

ALL EXTERNAL WIRING BETWEEN THE
APPLIANCE AND THE ELECTRICAL SUPPLY
SHALL COMPLY WITH I.E.E. WIRING
REGULATIONS.
If the wiring is extended or a completely new cable
fitted a 3-pin 13 amp plug should be fitted. (See Fig.
2a). Connect the wires as follows:
BROWN to the Live Terminal.
BLUE to the Neutral Terminal.
GREEN and YELLOW to the Earth Terminal.
As the colours of the wires in the mains lead which
you fit may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is GREEN and YELLOW must be
connected to the terminal in the plug which is
marked with the letter ‘E’ or by the earth symbol
or coloured GREEN or GREEN and YELLOW.
The wire which is coloured BLUE must be connected
to the terminal which is marked with the letter ‘N’ or
coloured BLACK.
The wire which is coloured BROWN must be
connected to the terminal which is marked with the
letter ‘L’ or coloured RED.

FIT A 3 AMP FUSE TO THE PLUG HOLDER.
Ensure that the supply cable cannot get caught by
the stability chain. Plug in the appliance.

INSTALLATION INSTRUCTIONS