CONNECTING TO THE MAINS TERMINAL


Warning: This appliance must be earthed.


We recommend you use a new length of 6mm

2

twin

core and earthed cable to ensure your safety.

Make connection as shown in Fig. 11 by proceeding

as follows:-

Preform wires to the appropriate shape to suit fitting

into the mains terminal block.

Strip inner insulation on wires using wirestrippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from the end of the inner

insulation. Where uninsulated Earth wires are used

ensure they are suitably sheathed to leave 10mm bare

wire to fit into the terminal.

Clamp bare wires into the relevant terminal and check

they are held by tugging each one in turn.

Clamp the mains cable securely ensuring 5mm of the

outer insulation is inside the terminal block and that

the wires are not taught but not so slack as to cause

any fouling. See Fig. 11.

Connect the remaining end to the mains cable to the

cooker point/junction box.

Place fuse/miniature circuit breaker in circuit and

switch on at mains.

CHECKING ELECTRICAL CONNECTIONS

Correct electrical connection can be confirmed when

switching on the appliance as the timer will be

flashing.

The electronic timer will flash on and off.

NOTE: HOUSE CIRCUIT

Earth leakage and continuity tests must be carried out

before the appliance is connected to the mains supply

and re-checked after fitting.

CONNECTING TO A HOB OR COOKER POINT

Either follow in general terms the instructions for

connecting to the terminal block or refer to the hob

suppliers installation instructions.

Feed the cable through the cabinet and arrange to

route the cable away from the appliance, which may

become hot.

Fig.11