Snvt table – MITSUBISHI ELECTRIC LMAP-02E User Manual

Page 8

Advertising
background image

02_NVspec_ver202e_pdf.xls 3_SNVT Table

3.SNVT Table

3.SNVT Table

3.SNVT Table

3.SNVT Table

Model

Model

Model

Model

nv No.

Name

CITY

Mr.SLIM

SNVT Type

input

output

(note 1)

(note 1)

MULTI

interlocks with
the indoor unit

operation from

L

ON

W

ORKS

Transmitted

when changing

Auto update

Initialize

(note 2)

1n

Request On/Off

nviOnOff_n

X

X

X

SNVT_switch

value

not used

-

-

-

state

X

-

-

-

2n

On/Off run state

nvoOnOff_n

X

X

X

SNVT_switch

value

-

not used

not used

not used

state

-

X

X

X

3n

Request Mode

nviMode_n

X

X

SNVT_hvac_mode

X

-

-

-

4n

Mode state

nvoMode_n

X

X

SNVT_hvac_mode

-

X

X

X

13n

Request LOSNNAY Mode

nviLCMode_n

X(note 3) SNVT_switch

value

X

-

-

-

state

X

-

-

-

14n

LOSSNAY Mode state

nvoLCMode_n

X(note 3)

X(note 3) SNVT_switch

value

-

X

X

X

state

-

not used

not used

not used

5n

SetPoint from network

nviSetPoint_n

X

X

SNVT_temp_p

X

-

-

-

6n

SetPoint state

nvoSetPoint_n

X

X

SNVT_temp_p

-

X

X

X

7n

Request Fanspeed

nviFanSpeed_n

X

X

X

SNVT_switch

value

X

-

-

-

state

not used

-

-

-

8n

FanSpeed state

nvoFanSpeed_n

X

X

X

SNVT_switch

value

-

X

X

X

state

-

not used

not used

not used

10n

Thermo On/Off state

nvoThermo_n

X

X

SNVT_state

-

X

-

-

12n

Temperature state of indoor

nvoSpaceTemp_n

X

X

SNVT_temp_p

-

X

X

-

16n

Alarm state

nvoAlarm_n

X

X

X(note 3)

X(note 3) SNVT_switch

value

-

not used

-

-

state

-

X

-

-

19n

Request Local Prohibit
On/Off

nviProOnOff_n

X

X

SNVT_switch

value

not used

-

-

-

state

X

-

-

-

20n

Local Prohibit On/Off
state

nvoProOnOff_n

X

X

SNVT_switch

value

-

not used

-

-

state

-

X

-

-

21n

Request Local Prohibit
mode

nviProMode_n

X

X

SNVT_switch

value

not used

-

-

-

state

X

-

-

-

22n

Local Prohibit mode state

nvoProMode_n

X

X

SNVT_switch

value

-

not used

-

-

state

-

X

-

-

23n

Request Local Prohibit
SetPoint

nviProSetP_n

X

X

SNVT_switch

value

not used

-

-

-

state

X

-

-

-

24n

Local Prohibit SetPoint
state

nvoProSetP_n

X

X

SNVT_switch

value

-

not used

-

-

state

-

X

-

-

11

Request All Off

nviAllOff

X

X

X

X

SNVT_switch

value

not used

-

-

-

state

X

-

-

-

NOTES:

1.

The value "n" is M-NET address of indoor unit

ex) Request On/Off to the 20th indoor unit.

nvNo :120

Name :nviOnOff_20

2.

The initialization of output can be changed by the setting of the configuration property.

3.

There is a case which cannot be used with the system configuration of the air conditioners units or the model of LOSSNAY.

LOSSNAY

WLN01-1023(Ver2.02)

- 15-

Advertising