Connecting External Controllers and
Analog Devices

You can connect an Ethernet-compatible controller such as AMX or Crestron to the amplifier’s [NETWORK]

connector, and remotely control the amplifier.

When connecting a remote controller, you must specify the amplifier’s Port No. The Port No. setting can be made

from the panel of the TXn amplifier or via Amp Editor. For details, refer to

page 21

or to the Amp Editor owner’s

manual.

• For details of the remote control communication protocol, please refer to the “TXn Remote Control Protocol Specification”

provided on the website.

http://www.yamahaproaudio.com/

You can connect a lamp etc. to the rear panel [FAULT OUTPUT] connector to

indicate that an abnormality has occurred.

The [FAULT OUTPUT] connector consists of NO (Normally Open), C (Common), and
NC (Normally Closed). The [FAULT OUTPUT] connector is a relay circuit, and oper-
ates as follows.

The relay contacts used in the [FAULT OUTPUT] connector are rated for a load of 1A, DC 30V. Do not apply a load that
exceeds this rating.
Use Amp Editor to make settings for the [FAULT OUTPUT] connector.
Euroblock plugs are used for the [FAULT OUTPUT] connector. Euroblock connection methods are described in

“Euroblock

plug connection” (page 52)

in this manual.

• In Amp Editor’s [Device Setup] menu

➝ [Alert Setup], you can set Type to Fault so that a fault can be indicated by a con-

nected lamp, etc. For details on making settings, refer to the “Amp Editor owner’s manual.”

• The relay contacts are rated for a resistive load of 1A, DC 30V. Do not apply a load that exceeds this rating.

Remote control from AMX or Crestron ([NETWORK] connector)

Controlling an analog device ([FAULT OUTPUT] connector)

Normal state

Abnormal state

Powered-off

NO

Open

Closed

Closed

NC

Closed

Open

Open

Example : Using an LED to indicate normal/fault status of the TXn

NOTE

NOTE

C

NC

NO

C

NC

NO

Normal state

Lit

Powered-off / Abnormal state

TXn

TXn

Unlit

Unlit

Lit

CAUTION