Connecting External Controllers and Analog Devices

Use the included Euroblock plug (3P) to make connections to the [FAULT OUTPUT] connector.

1.

Loosen the terminal screws.

• Use a slotted screwdriver with a blade approximately 2 mm wide.

2.

Insert the cables.

3.

Securely tighten the terminal screws.

Pull the cables (not too strongly) to confirm that they are securely connected.

4.

Connect the Euroblock plug to the TXn’s [FAULT OUTPUT] connector.

Euroblock plug connection

Cable preparation

• To prepare the cable for attachment to a Euroblock connector, strip the wire as

shown in the illustration, and use stranded wire to make connections. With a
Euroblock connection, the stranded wire may be prone to breakage because of
metal fatigue due to the weight of the cable or due to vibration. When rack-mount-
ing your equipment, use a lacing bar when possible to bundle and fasten the cables.

• If cables will be frequently connected and disconnected, as in the case of a portable

installation, we recommend that you use ferrules with insulation sleeves. Use a fer-
rule whose conductor portion has an external diameter of 1.3 mm or less, and a
length of approximately 5 mm (such as the AI0,5-6WH made by the Phoenix Con-
tact corporation).

• If you use stranded wire, do not tin (plate with solder) the exposed end.

approx.

5 mm

approx.

5 mm

1.3 mm

or less

CAUTION

NOTE

Euroblock plug

Slotted screwdriver

Terminal screw

Loosen

2 mm