York PREDATOR BP 090 User Manual

Page 13

Advertising
background image

259336-YTG-B-0606

Unitary Products Group

13

TABLE 7: HEATING APPLICATION DATA 7-1/2 TON HP HEAT (IMPERIAL)

CFM

ID DB

CAP & kW

OUTDOOR TEMPERATURE (°F) (72% RH)

-10

0

10

20

30

40

50

60

2250

55

MBH

26.1

31.8

38.7

47.1

57.3

69.8

85.0

103.6

KW

5.0

5.4

5.8

6.3

6.7

7.1

7.5

8.0

70

MBH

22.7

28.3

35.2

43.6

53.9

66.4

81.6

100.2

KW

5.8

6.2

6.6

7.0

7.5

7.9

8.3

8.7

80

MBH

18.9

24.6

31.5

39.9

50.1

62.6

77.8

96.4

KW

6.2

6.6

7.0

7.4

7.9

8.3

8.7

9.1

3000

55

MBH

29.2

34.9

41.8

50.2

60.4

72.9

88.2

106.7

KW

4.9

5.3

5.8

6.2

6.6

7.0

7.5

7.9

70

MBH

25.8

31.4

38.3

46.7

57.0

69.5

84.7

103.3

KW

5.7

6.1

6.5

7.0

7.4

7.8

8.2

8.7

80

MBH

22.0

27.7

34.6

43.0

53.2

65.7

81.0

99.5

KW

6.1

6.5

6.9

7.3

7.8

8.2

8.6

9.0

3750

55

MBH

34.0

39.6

46.5

54.9

65.2

77.7

92.9

111.5

KW

5.0

5.5

5.9

6.3

6.7

7.2

7.6

8.0

70

MBH

30.5

36.2

43.1

51.5

61.7

74.2

89.5

108.0

KW

5.8

6.2

6.7

7.1

7.5

7.9

8.4

8.8

80

MBH

26.8

32.4

39.3

47.7

58.0

70.5

85.7

104.3

KW

6.2

6.6

7.0

7.5

7.9

8.3

8.8

9.2

THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR.
FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x KW)