York PREDATOR BP 090 User Manual

Page 25

Advertising
background image

259336-YTG-B-0606

Unitary Products Group

25

TABLE 33: ELECTRIC HEAT MINIMUM SUPPLY AIR

- IMPERIAL

HEATER

UNIT MODEL SIZE,

NOMINAL TONS

kW

VOLTAGE

7.5

10

MINIMUM SUPPLY AIR CFM

9

380/415

2250

N/A

18

2250

3000

24

2250

3000

36

2250

3000

54

N/A

3000

TABLE 34: ELECTRIC HEAT MINIMUM SUPPLY AIR

- METRIC

HEATER

UNIT MODEL SIZE,

NOMINAL TONS

kW

VOLTAGE

7.5

10

MINIMUM SUPPLY AIR M

3

S

9

380/415

1.06

N/A

18

1.06

1.42

24

1.06

1.42

36

1.06

1.42

54

N/A

1.42

TABLE 35: INDOOR BLOWER SPECIFICATIONS

MODEL

MOTOR

MOTOR SHEAVE

BLOWER SHEAVE

BELT

HP

RPM

Eff.

SF

Frame

Datum Dia. (in.)

Bore (in.)

Model

Datum Dia. (in.)

Bore (in.)

Model

BP090

1-1/2

1725

80%

1.15

56

3.4 - 4.4

7/8

1VM50

7.5

1

AK79

A55

2

1725

80%

1.15

56

3.4 - 4.4

7/8

1VM50

6.5

1

AK69

A53

BP120

2

1725

80%

1.15

56

3.4 - 4.4

7/8

1VM50

7.0

1

AK74

A54

3

1725

80%

1.15

184T

4.3 - 5.3

1-1/8

1VP56

6.2

1

BK72

BX56

FIGURE 2 - UNIT 4 POINT LOAD

TABLE 36: 4 POINT LOAD WEIGHT

MODEL

LOCATION LBS. (KG)

A

B

C

D

BP090

242 (109)

207 (94)

301 (137)

353 (160)

BP120

265 (120)

226 (103)

330 (150)

386 (175)

D

A

C

B

L E F T

F R O N T

FIGURE 3 - UNIT CENTER OF GRAVITY

FIGURE 4 - UNIT 6 POINT LOAD

F R O N T

L E F T

4 1 "

( 1 0 4 0 )

2 4 "

( 6 1 0 )

N O T E : ( x x x ) i n d i c a t e s

d i m e n s i o n s i n

m i l l i m e t e r s

D

A

C

B

E

F

L E F T

F R O N T

Advertising