Features – York PREDATOR BP 090 User Manual

Page 3

Advertising
background image

259336-YTG-B-0606

Unitary Products Group

3

FEATURES

High Efficiency – High efficiency units reach as high as
9.1 EER.

Service Friendly – The Predator

®

incorporates a num-

ber of enhancements which improve serviceability.

The motor and blower slide out of the unit as a common
assembly. This facilitates greater access to all the indoor
airflow components, thus simplifying maintenance and
adjustment.

Service time is reduced through the use of hinged, tool-
less panels. Such panels provide access to frequently
inspected components and areas, including the control
box, compressors, filters, indoor motor & blower, and the
heating section. The panels are screwed in place at the
factory to prevent access by children or other unautho-
rized persons. It is recommended that the panels be
secured with screws once service is complete.

Service windows have been placed in both condenser
section walls. Rotation of the cover allows easy access
to the condenser coils for cleaning or inspection.

The unit control board utilizes flash codes to aid in diag-
nosis of unit malfunctions. Unique flash codes quickly
identify the source of the unit alarm.

All units use the same standard filter size. This stan-
dardization removes any confusion on which filter sizes
are needed for replacement.

The non-corrosive drain pan slides out of the unit to per-
mit easy cleaning. The drain pan is accessed by remov-
ing the drain pan cover plate on the rear of the unit.
Once the plate is removed, the drain pan slides out
through the rear of the unit.

All Predator

®

units have a second model nameplate

located inside the control access door. This is to prevent
deterioration of the nameplate through weathering.

FIGURE 1 - PREDATOR

®

COMPONENT LOCATION

Compressor #1 Access
(High-Eff Compressor)

Tool-less
Door Latch

Side entry power
and control wiring
knockouts

Slide-out drain pain
with steel 3/4” NPT
Connection

Belt-drive
blower
motor

Condenser
section

Filter drier (solid core)

Filter access
(2” throw-away)

Disconnect location
(optional disconnect switch)

Compressor #2
Access (High-Eff
Compressor)

Simplicity

Control board

w/screw connectors for T-
stat wiring and network
connection

Roof curbs in eight- and
fourteen-inch heights. Roof
curbs for transitioning from
Sunline™ footprint to the
BP series footprint are also
available (field installed
accessory)

Base Rails w/
Forklift Slots (3
Sides) & Lifting
Holes

Terminal block
for hi-voltage
connection

Dual stage cool-
ing for maximum
comfort (7-1/2 -
12-1/2 Only)

Second Model
Nameplate Inside
Control Door

Slide-out motor and
blower assembly for
easy adjustment and
service.

Advertising