Xantrex Technology FREEDOM HF 1800 User Manual

Page 17

Advertising
background image

975-0390-01-01

3

Introduction

Over-temp Alarm and Shutdown

During inverter mode, the Freedom

HF automatically alerts you if it is overheating and approaching the over-
temperature shutdown limit.

The Freedom HF automatically shuts down when the limit is exceeded.

Low Power Consumption

When the Freedom HF is inverting without a

load, it draws less than 1 amp of current from the battery (or battery bank).

This feature allows the unit to operate without draining too much stored
energy.

Battery-friendly Charging

For the inverter to perform effectively, the

batteries must be charged correctly. The Freedom HF has a built-in three-
stage charging system that extends the life and optimizes the performance
of the batteries.

In addition to the numerous features which let you maximize your battery’s
life and performance, the Freedom HF—unlike many chargers—also has
the ability to recharge a near-zero

1

voltage battery and an ignition-switched

20-amp auxiliary 12-volt power source

2

.

Selectable Low Battery Shutdown

The low battery shutdown for the

inverter can be manually selected by the user.

Ignition Control

The Freedom HF features the ability to inhibit the

inverter from operating in the absence of a voltage signal from a vehicle's
ignition circuit. This is particularly useful if the inverter is required to
operate only when a vehicle's engine is running.

1.Near-zero or dead batteries can be recharged. However, some batteries which have
been left uncharged for days can become severely damaged thus, recharging is futile.
2.Available on the Freedom HF 1055 EMS model and Freedom HF 1800 EMS model.
The inverter/charger features a 20-amp fused and switched output voltage supplied
from the inverter/charger's positive terminal. When connected to a vehicle's ignition
signal, a switched positive voltage is available to power auxiliary circuits that are re-
quired to operate only when the vehicle is operational.

Freedom HF 1800 T

All Other Models

Low Limit

11.8 volts

10.5 volts

High Limit

12.1 volts

11.8 volts

Freedom HF InvChg Owners Guide.book Page 3 Thursday, November 24, 2011 11:20 AM