14

Freedom HF Owner’s Guide

Freedom Inverter/Charger Operation

Display Panel Operation

The Freedom HF features a display panel with three-digit LED display to
show inverter, AC source, and battery status information.

Feature

Description

1

Inverter Power button

Press and hold for one second to turn the Freedom HF’s
Inverter function ON or OFF (when AC Shore Power is
NOT present.)

Press and hold for five seconds to adjust feature settings.
Go back to page 11 for instructions.

FREEDOM HF

Input Voltage (V)

Select

STATUS

Battery

Fault

Utility

Input Current (A)

Output Power (kW)

4

1

2

3

See NOTE in Feature # 4.

2

Three-digit LED display screen shows status information
and fault codes.

3

Status LED Indicates the mode of operation with a three-
color LED.

Green pertains to Utility status.

• Solid indicates the Freedom HF is in shore power

mode and battery is fully charged.

• Flashing indicates the Freedom HF is in shore

power mode and the unit is currently charging the
battery.

Yellow pertains to Battery status.

• Solid indicates the Freedom HF is in inverter

mode and using the battery to provide AC power.

• Flashing indicates the Freedom HF is in inverter

mode but AC shore power is detected thus
transferring to shore power mode within 20
seconds.

Red indicates a Fault condition and the Freedom HF has
shut down. See “Troubleshooting Reference” on page 36.

Feature

Description

Freedom HF InvChg Owners Guide.book Page 14 Thursday, November 24, 2011 11:20 AM