Xantrex Technology FREEDOM HF 1800 User Manual

Page 57

Advertising
background image

975-0390-01-01

43

Specifications

NOTE: These specifications refer to charger mode.

AC Input

Freedom HF 1000/1055 models

Freedom HF 1800 models

Operating voltage range

90–130 VAC

90–130 VAC

Nominal current

5 AAC at 20 A charge, 120 VAC IN

10 AAC at 40 A charge, 120 VAC IN

Nominal frequency

60 Hz

60 Hz

DC Input

Freedom HF 1000/1055 models

Freedom HF 1800 models

Nominal voltage

12.0 VDC

12.0 VDC

Min battery voltage for charging

0.0 VDC

0.0 VDC

Max output voltage

14.4 VDC

14.4 VDC

Nominal output current

User selectable:
2A, 5A, 10A, 20A (Freedom HF 1000)
5A, 15A, 35A, 55A (Freedom HF 1055)

User selectable:
2A, 10A, 20A, 40A

Charger current derating

Charger current will automatically derate as internal temperature exceeds 80 °C, and input VAC

approaches low transfer.

Efficiency at nominal output

75%

75%

Other

Freedom HF 1000/1055 models

Freedom HF 1800 models

Battery type settings

Flooded (default), Gel, AGM, or

Fixed (13.5V)

Charge algorithms

Three stages (Bulk, Absorption, and Float)

Independent battery banks

one (1)

Regulatory Approvals

Freedom HF 1000/1055 models

Freedom HF 1800 models

ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield with product

number 808-9531 required).

Freedom HF InvChg Owners Guide.book Page 43 Thursday, November 24, 2011 11:20 AM

Advertising