9

Freedom Inverter/Charger Configuration

Setting Battery Types on the Main Unit

You can attach different types of lead-acid batteries to the Freedom HF.
Before installing batteries make sure that you configure the unit to optimize
the charging process.

The settings can be changed by adjusting the dip switches found on the
main unit behind the display panel.

To adjust the battery type setting:

By default the battery type is set to Flooded (OFF|ON).

1.

Detach the Display Panel to expose the Dip Switches.

2.

Use the tip of your fingernail or a small screw driver with a flat tip to
adjust the switches.

Battery

Type

Dip Switch Setting

Switch 1|Switch 2

Bulk/

Absorption

Float

Fixed

OFF|OFF

13.5

13.5

Flooded

OFF|ON (default)

14.4

13.5

GEL

ON|OFF

14.2

13.8

AGM

ON|ON

14.3

13.4

Figure 2 Dip Switches (Default Settings Shown)

ON

OFF

Switch 1 | Switch 2