Xantrex Technology FREEDOM HF 1800 User Manual

Page 56

Advertising
background image

42

Freedom HF Owner’s Guide

Specifications

NOTE: These specifications refer to inverter mode.

DC Input

Freedom HF 1000/1055 models

Freedom HF 1800 models

Operating voltage range for all models

10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)

10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)

Operating voltage range for Freedom HF 1800 T

n/a

11.8–15.5 VDC (low limit)
12.1–15.5 VDC (high limit)

Safe non-operating voltage range

0–16 VDC

0–16 VDC

Normal voltage for all models

12.5 VDC

12.5 VDC

Nominal current at full load

100 ADC

180 ADC

AC Output

Freedom HF 1000/1055 models

Freedom HF 1800 models

Output voltage

115 VAC

115 VAC

Continuous power

1.0kW @ 25 °C

1.8kW @ 25 °C

Surge power

17 AAC
(2kW for 200 ms)

30 AAC
(3.6kW for 300 ms)

Max short-circuit current

55 AAC peak

55 AAC peak

Frequency

60 Hz

60 Hz

Wave shape

Modified Sine Wave

Modified Sine Wave

Power derating above 40 °C ambient temp

See “Invert Power Derating vs. Ambient Temperature” on page 28

Peak efficiency

87%

87%

Full load efficiency

80%

80%

Other

Freedom HF 1000/1055 models

Freedom HF 1800 models

No load input power (producing output voltage)

10W

10W

Off mode current draw

1mA

1mA

Freedom HF InvChg Owners Guide.book Page 42 Thursday, November 24, 2011 11:20 AM

Advertising
This manual is related to the following products: