OpeRatIOn

Settings

16

| FCR 28 | FCR 18 www.stiebel-eltron.com

4. settings

4.1 temperature

appliance type with external temperature selector
The temperature can be variably adjusted. In the delivered con-

dition, temperature selection is limited. This limitation can be

cancelled by a qualified contractor (see chapter "Installation /

Settings").
You can interrupt the heating process by setting the temperature

selector to "cold".

26

�02

�7

9�

002

7

• Cold

I Low temperature setting, 35 °C

II Recommended setting for energy saving,

low scaling, 60 °C

III Maximum temperature setting, 85 °C
Depending upon the system, the temperatures may vary from

the set value.
appliance type with temperature selector inside the control

panel
The temperature can be freely selected by the qualified contractor

(see chapter "Installation / Settings").
Factory setting: 60 °C

4.2 rapid heating during dual circuit operation

For appliance types with dual circuit operation, the heating con-

tractor can install a pushbutton to control the rapid heat-up func-

tion remotely. If required, you can switch this on. The rapid heat-

up function switches off when the selected temperature has been

reached and will not switch on again.

5. cleaning, care and maintenance

f

f Have the electrical safety of the appliance regularly checked

by an electrician.

scaling

f

f Almost every type of water will deposit lime at high tempera-

tures. Limescale will settle inside the appliance and affect its

function and service life. The heating elements must there-

fore be descaled from time to time. A qualified contractor

who is aware of the local water quality will tell you when the

next service is due.

f

f Check the taps/valves regularly. You can remove limescale

deposits at the tap outlets using commercially available des-

caling agents.

f

f Regularly activate the safety valve to prevent it from becom-

ing blocked e.g. by limescale deposits.

6. troubleshooting

Fault

Cause

Remedy

The water does not heat

up.

There is no power.

Check the fuses/MCBs in

your fuse box.

The temperature is incor-

rectly adjusted.

Check the temperature

setting.

The flow rate is low.

The aerator in the taps or

shower heads is dirty or

scaled-up.

Clean or descale the

aerator or shower head.

Water drips from the

safety assembly after

heating has stopped.

The valve seat is con-

taminated.

Depressurise and isolate

the appliance from the

power supply. Request

your qualified contractor

to attend.

If you cannot remedy the fault, notify your heating contractor. To

facilitate and speed up your enquiry, please provide the serial