Installation specification – STIEBEL ELTRON FCR 18-28 User Manual

Page 21

Advertising
background image

EN

GL

ISH

www.stiebel-eltron.com

FCR 28 | FCR 18 |

21

InStallatIOn

Specification

Fcr 28/270, part number 000696
27 kw, 3/Pe ~ 400 V

5

L3

L2

L1

4

4

3

1

2

26

�0

2�

79

�0

01

8

1 Heating element 3 kW

2 Contactor

3 High limit safety cut-out

4 Thermostat
connection example for single circuit operation with power-

oFF contact

5

L3

L2

L1

4

1

26

�0

2�

79

�0

05

0

1 Power-OFF contact, installed by the heating contractor

Fcr 28/360, part number 001502
36 kw, 3/Pe ~ 400 V

6

5

4

L3

L2

L1

4

3

1

2

26

�0

2�

79

�0

01

7

1 Heating element 4 kW

2 Thermostat

3 High limit safety cut-out

4 Contactor, installed by the heating contractor

!

Material losses

When connecting the contactors, please observe chapter

"Installation / Power connection".

Advertising