InStallatIOn

Commissioning

9.1 Power connection

WARNING Electrocution

Carry out all electrical connection and installation work

in accordance with relevant regulations.

WARNING Electrocution

Only use a permanent connection to the power supply.

Ensure that the appliance can be separated from the

power supply by an isolator that disconnects all poles

with at least 3 mm contact separation.

WARNING Electrocution

Ensure that the appliance is earthed.

!

Material losses

Observe the type plate. The specified voltage must match

the mains voltage.

f

f If required, pull off the temperature selector.

f

f Undo the screws at the bottom of the control panel cover and

remove the cover.

100

200

26

�0

2�

79

�0

04

9

f

f Select a cable of the cross-sectional area suited to the load

of the appliance. Prepare the power cable, ensuring that the

earth conductor is longer than the other conductors.

f

f Feed the power cable through the cable entry into the control

panel.

f

f Connect the required load in accordance with the wiring

diagrams (see chapter "Specification / Wiring diagrams and

connections").

f

f Fit the control panel cover.

f

f If required, push the temperature selector back on.

f

f Appliance type with dual circuit operation: Use a ballpoint

pen to mark the selected connected load and voltage on the

type plate.

!

Material losses

Contactors for thermostats or high limit safety cut-outs

must be installed outside the control panel of the flanged

immersion heater. The contactors must be switched inde-

pendently of one another by the thermostats and the high

limit safety cut-out respectively (see chapter "Specifica-

tion / Wiring diagrams and connections").

If the appliance is operated with power-OFF control, you must

install the power-OFF contact between the contactors or upstream

of the contactor.
Required contactor breaking capacity:

Sizing in accordance with the connected load (see chapter

"Specification / Data table") for l

e

/ AC-1 / 70 °C (thermal con-

stant current with a resistive load at an ambient temperature of

up to 70 °C).

f

f Label the contactors according to their function.

f

f If required, mark any live components inside the control

panel that are supplied with power from outside.

f

f Once connected, check that the contactors are functioning

properly.

10. commissioning

10.1 commissioning

f

f Fill the system with water.

!

Material losses

Boiling dry destroys the thermostat, which must then

be replaced. The high limit safety cut-out must be reset.

!

Material losses

If an indirect coil is installed in the same cylinder, limit

the maximum temperature for this appliance to the maxi-

mum temperature for the flanged immersion heater. This

prevents the high limit safety cut-out of the flanged im-

mersion heater from responding.

appliance handover

f

f Explain the appliance function to users and familiarise them

with its operation.

f

f Make users aware of potential dangers.

f

f Hand over these instructions.

10.2 recommissioning

See chapter "Commissioning".