Installation settings 11. settings, Troubleshooting, Maintenance – STIEBEL ELTRON FCR 18-28 User Manual

Page 19: 1 temperature, 2 limiting the temperature selection, 1 checking the safety assembly, 2 descaling the flanged immersion heater

Advertising
background image

EN

GL

ISH

www.stiebel-eltron.com

FCR 28 | FCR 18 |

19

InStallatIOn

Settings

11. settings

11.1 temperature

appliance type with temperature selector inside the control

panel

85°C

60°C

35°C

26

�02

�7

9�

002

8

Factory setting: 60 °C

11.2 limiting the temperature selection

appliance type with external temperature selector
You can adjust the temperature selection limitation beneath the

temperature selector.
Factory setting: 60 °C

f

f Set the temperature selector to "cold" and isolate the appli-

ance from the power supply.

f

f Remove the temperature selector and the control panel

cover.

f

f Loosen the two screws from the outside and pull the thermo-

stat down to remove.

f

f Once you have removed the limiter disc from the thermostat

axis, the maximum temperature can be reached.

f

f Tighten the thermostat screws again and replace the tem-

perature selector and control panel cover.

12. troubleshooting

Fault

Cause

Remedy

The water does not

heat up.

The high limit safety cut-

out has responded because

the controller is faulty.

Replace the thermostat and

press the high limit safety

cut-out reset button.

The high limit safety cut-

out has responded because

the temperature has fallen

below -15 °C.

Press the reset button.

A heating element is faulty.

Replace the heating ele-

ment or flanged immersion

heater.

The high limit safety cut-

out has responded because

an indirect coil in the same

cylinder is set too high.

Limit the maximum tem-

perature of the indirect

coil.

The safety valve drips

when the heating is

switched off.

The valve seat is contami-

nated.

Clean the valve seat.

1

26

�0

2�

79

�0

01

5

1 High limit safety cut-out reset button

13. maintenance

WARNING Electrocution

Before any work on the appliance, disconnect all poles

from the power supply.

13.1 checking the safety assembly

f

f Check the safety assembly regularly.

13.2 descaling the flanged immersion heater

f

f Descale the flanged immersion heater only after it has been

removed.

13.3 replacing the heating elements and protective

pipe

f

f When installing heating elements or a protective pipe, en-

sure that the components are electrically isolated from the

flange.

Advertising