Installation specification 14. specification, 1 dimensions, immersion depths and connections, 2 wiring diagrams and connections – STIEBEL ELTRON FCR 18-28 User Manual

Page 20: Fcr 28, Mating flange fcr 28, Fcr 18, Mating flange fcr 18

Advertising
background image

20

| FCR 28 | FCR 18 www.stiebel-eltron.com

InStallatIOn

Specification

14. specification

14.1 dimensions, immersion depths and connections

Fcr 28

325

280

225

D

00000

20

34

4

D

00000

20

34

4

mating flange Fcr 28

245

Ш 219

Ш 205

83

14

280

26

�0

2�

79

�0

01

3

Fcr 18

210

320

225

D

00000

32

23

2

mating flange Fcr 18

10

150

Ш 120

Ш 1

10

73

180

26

�0

2�

79

�0

01

4

14.2 wiring diagrams and connections

14.2.1 single circuit operation
Fcr 28/120, part number 000694

Fcr 28/180, part number 000695

Fcr 18/60, part number 000691

Fcr 18/90, part number 000692
6, 9, 12, 18 kw, 3/Pe ~ 400 V

5

L3

L2

L1

4

4

3

1

2

26

�0

2�

79

�0

01

6

1 Heating element

6 kW connected load: 3 x 2 kW

9 kW connected load: 3 x 3 kW

12 kW connected load: 6 x 2 kW

18 kW connected load: 6 x 3 kW

2 Contactor

3 High limit safety cut-out

4 Thermostat
connection example for single circuit operation with power-

oFF contact

5

L3

L2

L1

4

1

26

�0

2�

79

�0

05

0

1 Power-OFF contact, installed by the heating contractor

Advertising