7. safety

Only a qualified contractor should carry out installation, commis-

sioning, maintenance and repair of the appliance.

7.1 general safety instructions

We guarantee trouble-free function and operational reliability

only if the original accessories and spare parts intended for the

appliance are used.

7.2 instructions, standards and regulations

Note

Observe all applicable national and regional regulations

and instructions.

7.3 water connection and safety assembly

Note

Carry out all water connection and installation work in

accordance with regulations.

The cylinder must be connected with water inlet and outlet pipes

made from metal. Other metal parts of the cylinder that can be

touched and that are in contact with water must be permanently

and reliably connected with the earth conductor.

The max. permissible pressure must not be exceeded (see chapter

"Specification / Data table" and cylinder specification).

f

f Install a type-tested safety valve in the cold water supply

line. For this bear in mind that, depending on the static pres-

sure, you may also need a pressure reducing valve.

f

f Size the drain so that water can drain off unimpeded when

the safety valve is fully opened.

f

f Fit the discharge pipe of the safety valve with a constant

downward slope and in a room free from the risk of frost.

f

f The safety valve discharge aperture must remain open to the

atmosphere.

8. appliance description

8.1 standard delivery

Delivered with the appliance:

- Cable entries (supplied as loose parts depending on the ap-

pliance type)

- Fixing screws, corrugated washers

8.2 accessories

required accessories
Depending on the static pressure, safety assemblies and pressure

reducing valves are available. These type-tested safety assemblies

protect the appliance against unacceptable excess pressure.

Further accessories
A mating flange is available as an accessory.

9. installation

Note

For the installation of the appliance, the cylinder must

be fitted with a mating flange (see chapter "Appliance

description / Accessories").

Note

The control panel must not be thermally insulated to pre-

vent any excessively high temperatures from occurring

inside the control panel.

The condensate aperture in the flanged control panel

must remain open while the cylinder is thermally insulat-

ed so that any condensate that occurs can drip off freely.

f

f Observe the required torque values during installation (see

chapter "Specification / Data table").

f

f Always install the appliance horizontally with the cable en-

tries facing downwards.

f

f Always install the appliance with heating elements and a

protective pipe arranged in parallel. For this, use the screws

supplied. Realign the components where necessary.