VEGA Conductive electrodes User Manual

Page 11

Advertising
background image

Conductive measuring system

11

Product description

Electrical protective measures

Protection
- not mounted

IP 00

- mounted into

carrier BGT 596 Ex

front side completely equipped IP 30
upper and lower side IP 20
wiring side IP 00

- mounted into

housing type 505 Ex

IP 30

Protection class

II

Overvoltage category

II

Electrical connection

Mounted into
- carrier BGT 596 Ex

33-pole multipoint connector, series F (d, b, z)
with coding holes

- housing type 505 Ex

screw terminal, max. for 1,5 mm

2

CE-conformity

VEGATOR 532 Ex signal conditioning instrument meets the protective regulations of EMVG
(89/336/EWG) and NSR (72/23/EWG). The conformity has been judged acc. to the following
standards:
EMVG Emission

EN 50 081 - 1

Susceptibility

EN 50 082 - 2

NSR

EN 61 010 - 1

Signal conditioning instrument VEGATOR 631 Ex

General

Series

module unit with plug-in socket including
transparent cover, cover of the probe
terminals,
coded pin, 2 bridges

Dimensions

W = 36 mm, H = 118,5 mm, D = 134 mm

Weight

approx. 170 g

Mounting

carrier rail mounting acc. to DIN 46 277, Bl 3

Power supply

Operating voltage

20 … 250 V AC, 50/60 Hz
20 … 72 V DC

Power consumption

max. 1,5 W, approx. 1 … 9 VA

Fuse
- supply range

T 315 mA, 250 V

- switching power

min. 35 A at 250 V AC or 125 V DC