4 software update, 5 instrument repair – VEGA VEGAFLEX 66 (-20…+250°C) Profibus PA User Manual

Page 41

Advertising
background image

l

FX-E.60PX (X = without approvals)

l

FX-E.60PA (A = approvals CA, DA according to product list)

l

FX-E.60PC (C = approvals XM, CX, CM, CK, GX according to
product list)

8.4 Software update

The software version of VEGAFLEX 66 can be determined as follows:

l

on the type label of the electronics

l

via the indicating and adjustment module

l

via PACTware

You can view all software histories on our website www.vega.com.
Make use of this advantage and get registered for update information
via e-mail.

The following components are required to update the sensor software:

l

Sensor

l

Voltage supply

l

VEGACONNECT

l

PC with PACTware

l

Current sensor software as file

At "www.vega.com/downloads" go to "Software". Select under "plics
instruments and sensors
" the suitable instrument series. Load the zip
file via the right mouse key with "Save target as" e.g. on the desktop of
your PC. Extract all files available in the zip file, e.g. to the desktop.

Connect the sensor to power supply and provide connection from PC
to the instrument via VEGACONNECT. Start PACTware and provide
connection to the sensor, e.g. via the VEGA project assistant. Close
the parameter window of the sensor, as far as open.

Go in the PACTware menu bar to "Instrument data", "Additional
functions
" and "Update instrument software".

PACTware now checks the actual hardware and software version of
the sensor and displays the data. This procedure lasts approx. 60 s.

Push the button "Update software" and select the previously
extracted hex file. Then the software update can be started. The
additional files are installed automatically. Depending on the sensor,
this procedure can last approximately 1 h.

8.5 Instrument repair

If a repair is necessary, please proceed as follows:

You can download a return form (23 KB) from our Internet homepage
www.vega.com under: "D

ownloads - Forms and certificates - Repair

form".

By doing this you help us carry out the repair quickly and without
having to call back for needed information.

Load sensor software to
PC

Prepare update

Load software into sen-
sor

VEGAFLEX

66 • Profibus PA

41

8 Maintenance and fault rectification

34171

-

EN

-100427

Advertising