Additional deviation through strong, high
frequency electromagnetic fields acc. to EN
61326

50 mm

Specifications apply also to the current output

Temperature drift - Current output

±

0.03 %/10 K relating to the 16 mA span max.

±

0.3 %

Deviation on the current output by analogue/
digital conversion

15 µA

Deviation on the current output by strong,
high frequency electromagnetic fields within
EN

61326

150 µA

Influence of the superimposed gas and pressure to the accuracy

The propagation speed of the radar impulses in gas or vapour above the medium is reduced by
high pressure. This effect depends on the superimposed gas or vapour and is especially large at
low temperatures.

The following table shows the resulting deviation for some typical gases and vapours. The
specified values refer to the distance. Positive values mean that the measured distance is too
large, negative values that the measured distance is too small.

Gas phase

Temperature

Pressure

1

bar/

14

.5 psig

10

bar/

145

psig

50

bar/

725

psig

100

bar/

1450

psig

200

bar/

2900

psig

Air

20 °C/68 °F

0.00 %

0.22 %

1.2 %

2.4 %

4.9 %

200 °C/392 °F -0.01 %

0.13 %

0.74 %

1.5 %

3.0 %

400 °C/752 °F -0.02 %

0.08 %

0.52 %

1.1 %

2.1 %

Hydrogen

20 °C/68 °F

-0.01 %

0.10 %

0.61 %

1.2 %

2.5 %

200 °C/392 °F -0.02 %

0.05 %

0.37 %

0.76 %

1.6 %

400 °C/752 °F -0.02 %

0.03 %

0.25 %

0.53 %

1.1 %

Steam (satura-
ted steam)

100 °C/212 °F 0.26 %

-

-

-

-

180 °C/356 °F 0.17 %

2.1 %

-

-

-

264 °C/507 °F 0.12 %

1.44 %

9.2 %

-

-

366 °C/691 °F 0.07 %

1.01 %

5.7 %

13.2 %

76.0 %

Characteristics and performance data

Frequency

K-band (26 GHz technology)

Measuring cycle time

-

Standard electronics approx.

450 ms

VEGAPULS

62 • Approval according to LPR radio standard

67