Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)
-
Material
316Ti
-
Seal
FKM (Viton), FFKM (Kalrez 6375)
-
for tube diameter
6 mm
-
opening pressure
0.5 bar (7.25 psig)
-
Nominal pressure stage
PN
250
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
6)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap M20 x 1.5; 1 x blind stopper
M
20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
-
Double chamber housing
l
1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; 1 x blind stopper
M
16 x 1.5 or optional
7)
1 x plug M12 x 1 for
external indicating and adjustment unit
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½
NPT, 1 x blind stopper M16 x 1.5 or
optionally
8)
1 x plug M12 x 1 for external
indicating and adjustment unit
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally
9)
1 x plug M12 x 1 for external
indicating and adjustment unit
Spring-loaded terminals for wire cross-section
-
Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
-
Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
6)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
7)
Only with Ex d version
8)
Only with Ex d version
9)
Only with Ex d version
70
VEGAPULS
62 • Approval according to LPR radio standard
11 Supplement
41719
-EN
-120301