VEGA VEGAMIP R62 Receiving unit - Relay User Manual
Page 18
Advertising
2
1
2
2
1
1
Fig. 10: Front flush installation
1
Plastic or ceramic material
2
Fixing screw (if technically possible)
In very abrasive products, VEGAMIP 62 should be installed with a
mounting adapter or in front of a suitable window. In this case, you
have to use a window material which is appropriately resistant.
In case of strong vessel vibrations, the VEGAMIP 62 should be
mounted with anti vibration blocks or rubber buffers.
Abrasive medium
Vibrations