VEGA VEGAMIP R62 Receiving unit - Relay User Manual

Page 40

Advertising
background image

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

-

max.

Max. detection or overflow/overfill protection

-

min.

Min. detection or dry run protection

Measuring accuracy

Hysteresis

approximately 1 dB

Switching delay

adjustable from 0.1 … 20 s (on/off)

Min. distance

100 mm (3.94 in)

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of bulk solids and liquids

Process pressure

2)

-

VEGAMIP

62, threaded version - internal

horn antenna with PTFE cover

-1 … 4 bar/-100 … 400 kPa (-14.5 … 58 psig)

-

VEGAMIP

62, plastic encapsulated an-

tenna with PP cover

-1 … 2 bar/-100 … 200 kPa (-14.5 … 29 psig)

-

VEGAMIP

62, horn antenna/316L

-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psig)

-

VEGAMIP

62, encapsulated horn anten-

na with PTFE cover

-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)

-

VEGAMIP

62 with mounting adapter

unpressurized (IP 67)

Process temperature (thread or flange tem-
perature)

-

VEGAMIP

62, threaded version - internal

horn antenna with PTFE cover

-40 … +80 °C (-40 … +176 °F)

-

VEGAMIP

62, plastic encapsulated an-

tenna with PP cover

-40 … +80 °C (-40 … +176 °F)

-

VEGAMIP

62, horn antenna/316L - seal:

FKM (SHS FDM 70C3 GLT)

-40 … +130 °C (-40 … +266 °F)

-

VEGAMIP

62, horn antenna/316L - seal:

FFKM (Kalrez 6375)

-20 … +130 °C (-4 … +266 °F)

-

VEGAMIP

62, encapsulated horn anten-

na with PTFE cover

-40 … +200 °C (-40 … +392 °F)

-

VEGAMIP

62 with mounting adapter

150 mm (optional)

-40 … +250 °C (-40 … +482 °F)

-

VEGAMIP

62 with mounting adapter

300 mm (optional)

-40 … +450 °C (-40 … +842 °F)

2)

Note max. pressure of the process fitting