6

Setup

6

.1 Adjustment elements

The figures in brackets refer to the following illustration.

6

7

9

8

4

5

1

2

3

1

L N

3

(-)

( )

4 5 6 7 8

2

+

3 4 5 6 7 8

Fig. 23: Electronics module MP6X R (receiving unit) - Relay output

1

Mode switch for selecting the switching behaviour (min./max.)

2

Control lamp (LED) for indication of a fault (red)

3

Signal lamp (LED) for indication of the switching status (yellow)

4

Control lamp (LED) for indication of the instrument function (green)

5

Connection terminals

6

Ground terminal

7

Key for adjustment of the sensitivity and the switching delay (-->)

8

Key for adjustment of the sensitivity and the switching delay (<--)

9

LED indicating board for indication of reception strength (yellow)

There are three control lamps (LED) on the electronics module

Control lamp (red) for indication of a fault (2)
This signal lamp shows the fault status of the instrument.

Control lamp (yellow) for indication of the switching condition (3)
The signal lamp signals the switching condition of the switching output.

Control lamp (green) for indication of the instrument function (4)
The green signal lamp (on) shows the operating state of the instrument
as soon as voltage supply is connected correctly.

Signal lamps (2, 3, 4)

VEGAMIP R

62 • - Relay

29

6 Setup

41912

-

EN