3 ulsm typical example, Ulsm, Ypical – QTECH QSW-8300 Инструкция по настройке User Manual

Page 325: Xample

Advertising
background image

+7(495) 797-3311 www.qtech.ru

Москва, Новозаводская ул., 18, стр. 1

324

35.3 ULSM Typical Example

ULSM typical example

The above topology is the typical application environment which is used by ULSM and ULPP

protocol.

ULSM is used to process the port state synchronization, its independent running is useless, so

it usually associates with ULPP protocol to use. In the topology, SwitchA enables ULPP

protocol, it is used to switch the uplink. SwitchB and SwitchC enable ULSM protocol to monitor

whether the uplink is down. If it is down, then ULSM will execute the down operation for the

downlink port to shutdown it, so ULPP protocol of Swtich A executes the relative operation of

the uplink switchover.

SwitchA configuration task list:

Switch(Config)#spanning-tree mst configuration

Switch(Config-Mstp-Region)#instance 1 vlan 1

Switch(Config-Mstp-Region)#exit

Switch(Config)#ulpp group 1

Switch(ulpp-group-1)#protect vlan-reference-instance 1

Switch(ulpp-group-1)#exit

Switch(Config)#interface ethernet 1/0/1

Switch(config-If-Ethernet1/0/1)# ulpp group 1 master

Switch(config-If-Ethernet1/0/1)#exit

Switch(Config)#interface Ethernet 1/0/2

Switch(config-If-Ethernet1/0/2)# ulpp group 1 slave

Switch(config-If-Ethernet1/0/2)#exit

SwitchB configuration task list:

Switch(Config)#ulsm group 1

SwitchB

E1/0/1

SwitchD

SwitchA

E1/0/2

SwitchC

E1/0/2

E1/0/

1

E1/0/3

E1/0/

4

Advertising