A .3 Commands for Client Mode

SERV <IP Address: Port> [bdaddr|name]

:

To assign IP address of Host and port number Client Mode MSP may

access. If you enter BD address of Device name of the Bluetooth terminal,

you may configure different Host address for each Bluetooth terminals.

Response:

index|name|bdaddr|server_IP: port

Ex.:

SERV 192.168.1.11:9000

+OK

SERV 192.168.1.11:9001 Parani10

+OK

SERV

0|Parani10||192.168.1.11:9001

+OK 192.168.1.11:9000

DELSERV <bdaddr|name>

:

To delete Host information stored by SERV command.

Ex.:

DELSERV Parani10

+OK

REPT <interval>

:

When connection to Host is fails, users may configure a connection retrial

period. Unit: millisecond, Default value: 5000 ms

If the value is ‘0’, Parani100 will not try to connect after first failure.

Ex.:

REPT 3000

+OK REPEAT every 3000 ms

PSIST <on|off>

:

In Client mode, in the event of TCP disconnect, Parani100 automatically

attempts Host PC reconnect when PSIST is set to ON, in the period of

pre-defined ms by REPT command.

Ex.:

PSIST ON

+OK PERSIST on