A .8 other commands – SENA Parani100 User Manual

Page 59

Advertising
background image

- 59 -

59

A .8 Other Commands

DUMP [idx] [bin]

:

This command can be used for monitoring with a Bluetooth terminal.

[idx]: To select a specific device to monitor. (255 means all of devices)

[bin]: To send the monitored data in binary format.

Format: <dir:1><idx:1><length:2><timestamp:4><data… :length>

Timestamp: in milliseconds

Ex.:

DUMP

> line 0 len 4 timestamp 1413986

61 62 63 64

abcd

< line 0 len 4 timestamp 1414056

4F 4B 0D 0A

OK..

+OK

HELP

:

HELP command displays all control commands available.

Ex.:

HELP
+OK

VER

:

To see software version no. of Parani100

Ex.:

VER

+OK Ver 1.7

CTRL <port no.>

:

Control port default value is ‘2525’.

CTRL command assigns new control

port number.

Revised control port no. is applied after Parani100restart.

Default CTRL displays current control port number value.

Ex.:

CTRL 3500

+OK

CANCEL

:

To cancel current operation

Ex.:

CANCEL

+OK