SENA ProBee-ZE20S User Manual

Page 44

Advertising
background image

44

ProBee-ZE20S User Guide Rev.1.10

Table 5-2 Special GPIO Pins

Function

GPIO#

Type

Description

Factory_reset

/ Bootloader

-

DI

This input is dedicated for the factory reset button. If user wants to

restore the ZE20S device settings to factory default, this input (falling

edge, i.e. High to Low change) needs to be pressed for more than two

seconds. It will be applied after the input released again. If this input is

pressed while the ZE20S starts, the local node enters bootloader

menu and it is possible to upload the firmware. Factory reset button is

not available when the ZE20S device is sleeping.

Permit_joining

/ Wake-up

0

DI

This input (falling edge, i.e. High to Low change) is used to permit

joining or interrupt sleeping. This function is activated when GPIO0 is

set to 5. The functions depend on the node type of the ZE20S. If the

node is set to coordinator or router, this input works to permit other

nodes joining for Permit joining timeout(S-register 22 value). If the

node is set to sleepy end-device, it is used for wake-up signal when

the node is sleeping.

UART_CTS

1

DI

This input is used for UART CTS if GPIO1 is set to 5. It should be

enabled when CTS flow control is used.

UART_RTS

2

DO

This output is used for UART RTS if GPIO2 is set to 5. It should be

enabled when RTS flow control is used.

UART_DTR

3

DO

This output is used for UART DTR if GPIO3 is set to 5.

UATR_DSR

4

DI

This input is used for UART DSR if GPIO4 is set to 5.

Power LED

15

DO

If GPIO15 is set to 5, this output turns ON (High) when power is

supplied. If the node is set to an end-device, it will blink periodically.

Please refer to 9 S-Registers for S14 regarding the management of

the LED status.

Status LED

16

DO

If GPIO16 is set to 5, this output turns ON (High) when the device

joins a network, blinks when joining is permitted, and turns OFF (Low)

when leaves the network. Please refer to 9 S-Registers for S14

regarding the management of the LED status.

5.2

I/O Sampling

The I/O status can be monitored and controlled using the AT commands. The I/O status of remote device

can be monitored and controlled using remote AT commands, too. The ZE20S can also be configured to

sample the I/O status and send to a remote device periodically.

5.2.1

Queried Sampling

The I/O status can be monitored and controlled using the AT commands either locally or remotely. To read