SENA ProBee-ZE20S User Manual
Page 55
55
ProBee-ZE20S User Guide Rev.1.10
6.5
Configuration Example #2: 1 Coordinator and 2 End-Devices
Here is another example assuming different system configurations. This example can be described as
follows:
One ZE20S module acts as a coordinator and it is connected to a host computer via serial cable.
Two ZE20S modules act as end-devices.
Turn on/off the LEDs of the end-devices remotely through the coordinator
Figure 6-4 Example #2: 1 Coordinator and 2 End-Devices
6.5.1
Coordinator Configuration
Hardware configuration for the coordinator is as follows:
Set the HOST switch to UART
Connect a serial cable between a host computer and the coordinator
The AT commands for coordinator configuration is as follows:
AT+NODETYPE=1
OK
AT+PANID=7772
OK
ATZ
OK
6.5.2
End-devices Configuration
Hardware configuration for the coordinator is as follows:
Set the GPIO_OUT switch to LED_ON
The AT commands for the end-devices are as follows:
AT+NODETYPE=4
OK