ProBee-ZE20S User Guide Rev.1.10

AT+LINKKEY=5A46…21<CR>

# set the 128-bit trust center link key (5A46…21)

ATZ<CR>

# Apply the change

OK

# Response

AT+NWKKEY=0<CR>

# set the 128-bit network key (random key)

OK

# Response

AT+UPDATEKEY<CR>

# update the changed network key

OK

# Response

8.4

UART Settings

AT+BAUDRATE=115200<CR>

# set baud rate (115,200bps)

OK

# Response

AT+DATABIT=8<CR>

# set data bit (8bit)

OK

# Response

AT+PARITY=0<CR>

# set parity (none)

OK

# Response

AT+STOPBIT=1<CR>

# set stop bit (1bit)

OK

# Response

AT+FLOWCTRL=2<CR>

# set flow control (hardware)

OK

# Response

ATZ<CR>

# Apply the change

OK

# Response

8.5

GPIO

AT+GPIO=55003300000441122<CR> # set GPIO configuration

OK

# Response

ATZ<CR>

# Apply the change

OK

# Response

AT+GPIO0<CR>

# check the current GPIO status (GPIO0)

5

OK

# Response

AT+DIO<CR>

# check the current DIO value

10000000000**0011

OK

# Response

AT+AI<CR>

# check the current AI value

****,****,1786,23A2,****,****

OK

# Response