SENA ProBee-ZE20S User Manual

Page 91

Advertising
background image

91

ProBee-ZE20S User Guide Rev.1.10

device to poll more rapidly for a short time when receiving RF data.

Execute

ATS56?<CR>

ATS56=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

5

Range

0 - 10000

9.6

Sink

9.6.1

S61

Description

Get/Set the sink node and the sink advertise period in seconds. When a node is

defined as a sink, it can multicast its address to the rest of the network in this period. If

set to 0, sink advertise is disabled.

Execute

ATS61?<CR>

ATS61=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

0

Range

0 – 10000

9.6.2

S62

Description

Get/Set the period to send Many-to-One Route Request. Many-to-One Route Request

(MTOR) creates routes from every node in the network back to this node. It is useful

when this node acts as a sink node.

Execute

ATS62?<CR>

ATS62=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

0

Range

0 – 10000

9.7

Frequency Agility

9.7.1

S71

Description

Get/Set the Frequency agility function. If it is enabled in coordinator mode, node will

automatically shift operating channel to one of channel masks when its unicasts fail

more than threshold.

Execute

ATS71?<CR>

ATS71=<value><CR>

Response

<value><CR>

OK<CR>

OK<CR>

Default

0

Range

0 – 1

Advertising