3d. motor data tabulation

Before commissioning, it is recommended to record the actual motor nameplate data. Also record gearbox, and
attached roll diameter, or any appropriate mechanical data that may be needed during setup.

This table may be used as a guide to record motor nameplate and application data

Typical DC Motor Nameplate

HP (kW)

RPM

Volts

Arm Amps
Fld Amps

Fld ohms 25 C

Fld is an abbreviation for field

Gear in speed

· :

rpm

· gear in speed is the top motor rpm to achieve rated machine speed

Acceleration time · :

seconds

· :

seconds

: constant current, (fixed field current)

field weakening (see example below)

: analog

V /

RPM

digital tacho into Encoder 2

PR

None

P

(circle one)

(circle one)

tachometer type
and calibration

see jumpers in 3.f.

see jumpers in 3.f.

see jumpers note in 3.f.

Deceleration time

Field control

Nameplate dual speed rating

The value for RPM may be represented with two values, the first representing base speed , which is the rpm at
nameplate volts and nameplate field current.

A second RPM value, if shown, corresponds to rated top speed, which is achieved at rated nameplate volts, and
a weak field setting. The weak field setting would correspond to the second value of field amps.

For the nameplate below, base speed is 1750 rpm @ 3 amps field and top speed is 2300 rpm @ 1 amp field

Typical DC Motor Nameplate

HP (kW)

20

RPM

1750 / 2300

Volts 500

Arm Amps 32
Fld Amps

3.0 / 1.0

Fld ohms 25 C

72

Verify the motor data matches the drive power rating, output voltages, and required motor speed is achievable.

If files in the GE Control System Toolbox were predefined off-line, verify the entered data is correct before