12c. Configure jog operation

Jog is setup using TBO discrete inputs (unless a LAN
is being used). Jog can be setup with several options:
ramped or step, analog reference or internal setpoint.

First the jog function must be enabled.

Press ENT

press the down arrow

Press ENT

Press ENT

press the + key to enable. Press ENT.

For internal jog speed reference, now press the down
arrow twice to show:

using the + and - keys, select Speed input for a step
reference, select Ramp input for a ramped jog using
the main ramp, press ENT.

For internal jog speed reference, now press the down
arrow to show:

enter the desired rpm reference, using the arrow keys
and + and - key, press ENT.

If an analog jog reference is desired, review section
12.b.Press the CANC key to get back to:

Press the down arrow key until this screen is shown:

Press ENT

Press the down arrow key three times to show :

Press ENT

Press the + key to set [Jog stop control] = ON.

Press ENT.

This setting operates the jog the same as the default
stop control for the drive. When the jog is commanded
the relay 2 output picks up ( to pickup the AC or DC
contactor ) and allow to run.

Now, the commands for jog need to be configured.

Press the CANC button twice, and then the up arrow
twice to get to menu:

Press ENT

press the down arrow thrice to get to:

Press ENT

Arrow down key to the digital input desired to be used
for jog + (jog forward), press ENT

Press CANC to get back to:

Press ENT

Arrow down key to the digital input desired to be used
for jog - (jog reverse), press ENT.

Follow steps repeated previously to SAVE parameters.