15. QUICK TROUBLESHOOTING

15a. Regulation card testpoints

Test point

name and description

notes

XY5

+5V , processor power supply

XY6

GNDD, +5V processor power supply ground

XY7

GNDD, +5V processor power supply ground

XY8

+24V, 24 VDC power supply

XY9

GNDV, 24 VDC power supply common

XY10

GNDA, 15 V power supply common

XY11

-15 V power supply

XY12

+15 V power supply

XY17

current feedback, scaling .61V = 1 P.U. of the drive rating

XY18

common

XY19

armature voltage feedback

XY20

select output

XY21

attenuated AC input signal, V-U

XY22

attenuated AC input signal, V-W

15b. Failure messages and troubleshooting hints

Message

Possible causes

Hints

Failure Supply

blown power supply fuse, bad power supply

check 24 V I/O for shorts to ground replace power
supply fuse, remove I/O connectors to isolate
wiring

Undervoltage

Parameter [ Undervoltage thres] set too high

check parameter [Undervoltage thres] setting

AC line has excessive noise or ringing

missing an incoming reactor

AC line is soft

too much incoming reactor/transformer impedance

bad power connections

check all power connections

the drive has been enabled without bridge power

AC input contactor didn’t pick up

Overvoltage

Too much voltage on the DC output

parameter [max output voltage] set too low

field current set too high for speed

check field current parameters

this trip occurs at 1.2 times parameter [max

crossover % set too high

output voltage]

Heatsink

heatsink temperature is too hot

failure of a door fan, or drive fan
heatsink is dirty or clogged
loss of fan power
failed sensor

Overtemp motor failure in the motor overtemp circuit

input TB 79 & 79 is open circuit,
bad wiring , thermistor, or klixon

motor is too hot

motor blower is failed, or off
ventilation is blocked
overloaded motor, improper setup
ambient temperature is too high
self cooled motor running at low speeds at high
loads

Advertising