GEH-6129

—————— Quick Start up guide ——————

QS

16

Press the down arrow to go to the next parameter.

Motor data
Full load current

Press ENT

Enter the nameplate armature amps as recorded
in section 3d. . press ENT

Press the down arrow to go to the next parameter.

Motor data
Motor max speed

Press ENT

Enter the same rpm as entered for speed base value(
rated motor rpm recorded from section 3 d.,
corresponding to the maximum desired motor rpm
), press ENT

Press the down arrow to go to the next parameter.

Motor data
Max output volts

Default = 500 VDC press ENT to change

Enter the nameplate output volts as recorded from
section 3 d, if different from default, press ENT

Press CANC to return to Motor data menu, and press
the down arrow to go to the next parameter menu.

START UP
Limits

The default settings for these are adequate for most
applications @ 500 VDC and 150% OL for 1 minute.

The list below shows some possible applications re-
quiring user changes to “Limits” parameters:

-

For weak field operations:

If

top speed field current

speed field current

base

< .7

then “START UP \ Limits \ Flux current min “

will

need adjusted

-

230 VAC operation - also change [prog alarms
\ undervoltage threshold] , and Motor data ....

-

Overload capacities different than 150% for 60
seconds, [Overload contr] and [ T curr limit]

Press the down arrow to go to the next parameter menu.

START UP
Speed feed-back

Press ENT

Speed feed-back
Speed feed-back sel

Press ENT

Use the + arrow to select speed feedback type =
armature, press ENT

Press CANC to return to

START UP
Speed feed-back

the default settings are already set for speed control
using a potentiometer wired to analog input, skip to
SAVE PARAMETERS.

For keypad control of speed reference, go to menu
selection.

START UP
Analog inputs

Press ENT

Analog inputs
Analog input 1

Press ENT

Analog inputs
Analog input 1 sel

Press ENT

Hold in the - key until entry shows OFF,