Programming, 6. advanced block parameters -adv – GE Industrial Solutions ASTAT-IBP Plus User Manual

Page 20

Advertising
background image

D x x x

A x x x

X x x x

X P x x

s x x x

4. Programming

4-7

Function

Display

Description

Default

Range

Unit

4-6. Advanced block parameters -ADV-

Lock-out

E2PROM reading

Factory settings

Undervoltage

Undervoltage trip time

Overvoltage

Overvoltage trip time

Undercurrent

Undercurrent trip time

Overcurrent

Overcurrent trip time

Dual Ramp Up
Dual Ramp Down
Dual StartingTorque

L K x x

R x x x

Q x x x

U V x x

u v x x

O V x x

o v x x

U C x x

u c x x

O C x x

o c x x

2 a x x
2 d x x
2 T x x

L K 0 5

R O F F

Q O F F

U V 0 0

u v 2 0

O V 0 0

o v 2 0

U C 0 0

u c 2 0

O C 0 0

o c 2 0

2 a 1 5
2 d 2 0
2 T 2 5

Sets time between consecutive starts. Setting "0" disables
this function.

Loads the parameters from the E2PROM to the temporal
buffer.

Loads default factory settings to the temporal buffer.
Resave to E2PROM if default settings are desired.

The unit trips if the line voltage on Leg L1 decreases below
the percentage set. Setting “0” disables this protection.
NOTE:

Perform voltage calibration procedure on page
4-5 before enabling this protection.

Delay trip time.

The unit trips if the line voltage on Leg L1 increases above
the percentage set. Setting “0” disables this protection.
NOTE:

Perform voltage calibration procedure on page
4-5 before enabling this protection.

Delay trip time.

The unit trips if the current decreases below the percentage
set. Setting “0” disables this protection.
NOTE:

Perform current calibration procedure on page
4-5 before enabling this protection.

Delay trip time.

The unit trips if the current increases above the percentage
set. Setting “0” disables this protection.
NOTE:

Perform current calibration procedure on page
4-5 before enabling this protection.

Delay trip time.

These are a secondary set of ramp up, ramp down and
starting torque parameters, which take over the primary "a",
"d" and "T" when the programmable function “A” is enabled.

00-45

ON, OFF

ON, OFF

00-50

00-99

00-30

00-99

00-99

00-99

00-50

00-99

01-45
01-60
10-90

min.

-

-

%

sec.

%

sec.

%

sec.

%

sec.

%
%
%

4-6-1. Advanced functions

Function

Display

Description

Default

Range

4-6-2. Programmable advanced functions

Linear ramp

Dual motor selector

Remote control selector

Comunication protocol

Station number

D O F F

A O F F

X O F F

X P 0 0

s 0 0 1

This function provides linear acceleration and deceleration ramps in a
wider range of load conditions using tachogenerator feedback.
A DC Tacho-Generator coupled to motor must be used to provide an
analog signal feedback of 0-5VDC to terminals 7 and 8.

This function allows dual motor control settings of acceleration,
deceleration and starting torque, and is useful to start or stop a motor
in diferent load conditions.
When this function is enabled, the parameters 2a, 2d and 2T take over
the parameters a, d and T. It allows dual motor control settings.

Allows serial communication control by SG, TD and RD terminals.
Check Appendix section for more details.
Sets serial communications protocol.
0: ASCII

1: Future use

2: Future use

ASCII protocol allows a maximum of 90 stations only.

OFF, ON, I3, I4

OFF, ON, I3, I4

OFF, ON, I3, I4

00-02

001-247